YASKAWA L1000A Technical Manual page 411

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

H2-
Function
Setting
5
Speed Detection 2
6
Drive Ready (READY)
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Speed Reference Source
A
Up/Down Command Source
B
Torque Detection 1
E
Fault
F
Not used (Through Mode)
10
Minor Fault
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-set Speed Agree 2
15
Speed Detection 3
16
Speed Detection 4
18
Torque Detection 2
1A
During Down Direction
1B
During Baseblock 2 (N.C.)
1C
Motor 2 Selection
1D
During Regeneration
1E
Reset Enabled
1F
Motor Overload Alarm (oL1)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
H2 Multi-Function Digital Output Settings
All Modes
Closed: Output speed is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.
All Modes
Closed: Power up is complete and the drive is ready to accept an Up/Down command.
All Modes
Closed: DC bus voltage is below the Uv trip level set in L2-05.
All Modes
Closed: Drive has entered the baseblock state (no output voltage).
All Modes
Open: The speed reference is supplied by an external reference (set in b1-01).
Closed: Digital operator supplies the speed reference.
All Modes
Open: The Up/Down command is supplied by an external reference (set in b1-02).
Closed: Digital operator supplies the Up/Down command.
All Modes
Closed: An overtorque or undertorque situation has been detected.
All Modes
Closed: Fault occurred. (excluding CPF00 and CPF01)
All Modes
Set this value when the terminal is not used or when using the terminal in the pass-through mode.
All Modes
Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.
All Modes
Closed: The drive has received a reset command from the multi-function input terminals or from serial network, or the
digital operator's RESET key has been pressed.
All Modes
Closed: Timer output.
All Modes
Closed: When drive output frequency equals the speed reference ±L4-04.
All Modes
Closed: When the drive output speed is equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the drive output speed is less than or equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the output speed is greater than or equal to the value in L4-03 ±L4-04.
All Modes
Closed: Overtorque or undertorque has been detected.
All Modes
Closed: Drive is running in the down direction.
All Modes
Open: Drive has entered the baseblock state (no output voltage).
V/f
OLV
Open: Motor 1 is selected
Closed: Motor 2 is selected
V/f
OLV
Closed: Motor is operated in regenerative mode.
All Modes
Closed: An automatic reset is performed
All Modes
Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.
Description
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Page
common_
TMonly
210
common_
TMonly
211
common_
TMonly
211
common_
TMonly
211
common_
TMonly
211
common_
TMonly
211
common_
211
TMonly
common_
TMonly
212
common_
TMonly
212
common_
TMonly
212
common_
TMonly
212
common_
TMonly
212
common_
TMonly
212
common_
TMonly
212
common_
TMonly
213
common_
TMonly
213
common_
TMonly
211
common_
TMonly
214
common_
TMonly
214
common_
TMonly
214
common_
TMonly
215
common_
TMonly
215
common_
TMonly
215
B
411