No.(Addr.)
Name
F4-05
(395H)
Terminal V1 Bias
F4-06
(396H)
Terminal V2 Bias
F4-07
Terminal V1 Signal Level
(397H)
Selection
F4-08
Terminal V2 Signal Level
(398H)
Selection
F5: Digital Output Card (DO-A3)
No.(Addr.)
Name
F5-01
Terminal P1-C1 Output Selection
(399H)
F5-02
Terminal P2-C2 Output Selection
(39AH)
F5-03
Terminal P3-C3 Output Selection
(39BH)
F5-04
Terminal P4-C4 Output Selection
(39CH)
F5-05
Terminal P5-C5 Output Selection
(39DH)
F5-06
Terminal P6-C6 Output Selection
(39EH)
F5-07
Terminal M1-M2 Output Selection
(39FH)
F5-08
Terminal M3-M4 Output Selection
(3A0H)
F5-09
DO-A3 Output Mode Selection
(3A1H)
F6: Communication Option Card
For more details on a specific option card, refer to the instruction manual for the option card.
No.(Addr.)
Name
F6-01
Operation Selection after
(3A2H)
Communications Error
External Fault from
F6-02
Communication Option Detection
(3A3H)
Selection
External Fault from
F6-03
Communication Option Operation
(3A4H)
Selection
F6-04
bUS Error Detection Time
(3A5H)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
All Modes
Sets the amount of bias added to the voltage output via terminal V1.
All Modes
Sets the amount of bias added to the voltage output via terminal V2.
All Modes
0: 0 to 10 V
1: -10 to 10 V
Description
All Modes
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output
terminals P1 through P6.
All Modes
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through F5-08.
Description
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.
All Modes
0: Always detected
1: Detection during run only
All Modes
0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.
All Modes
Sets the delay time for error detection if a bus error occurs.
B.3 Parameter Table
Setting
Page
Default: 0.0%
common_
TMonly
Min: -999.9%
199
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
199
Max: 999.9%
Default: 1
Min: 0
200
common_
Max: 1
TMonly
Default: 1
Min: 0
200
Max: 1
Setting
Page
Default: 0
Min: 0
200
Max: 161
Default: 1
Min: 0
200
Max: 161
Default: 2
Min: 0
200
Max: 161
Default: 4
Min: 0
200
common_
Max: 161
TMonly
Default: 6
Min: 0
200
Max: 161
Default: 37
Min: 0
200
Max: 161
Default: F
Min: 0
200
Max: 161
Default: F
Min: 0
200
Max: 161
common_
TMonly
Default: 0
Min: 0
200
Max: 2
Setting
Page
common_
TMonly
Default: 1
Min: 0
201
Max: 3
common_
Default: 0
TMonly
Min: 0
201
Max: 1
common_
TMonly
Default: 1
Min: 0
201
Max: 3
Default: 2.0 s
common_
TMonly
Min: 0.0 s
Max: 5.0 s
B
407