Drive Model
Nominal
CIMR-LU
Output Power
40150
40180
125 - 150
40216
40304
40370
40450
40605
400 - 500
50003
50004
50006
50010
50013
50017
50022
50027
50032
50041
50052
50062
50077
50099
50130
50172
50200
<1> Maximum MCCB Rating is 15 A, or 200% of drive input current rating, whichever is larger. MCCB voltage rating must be 600 Vac or greater.
<2> Maximum Time Delay fuse is 175% of drive input current rating. This covers any Class CC, J or T class fuse.
<3> Maximum Non-time Delay fuse is 300% of drive input current rating. This covers any CC, J or T class fuse.
<4> Class L fuse is also approved for this rating.
Low Voltage Wiring for Control Circuit Terminals
Wire low voltage wires with NEC Class 1 circuit conductors. Refer to national state or local codes for wiring. If external
power supply used, it shall be UL Listed Class 2 power source only or equivalent. Refer to NEC Article 725 Class 1,
Class 2, and Class 3 Remote-Control, Signaling, and Power Limited Circuits for requirements concerning class 1 circuit
conductors and class 2 power supplies.
Input / Output
Open Collector Outputs
Digital inputs
Analog inputs / outputs
Drive Short Circuit Rating
This drive is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes,
600 Vac maximum (Up to 240 V in 200 V class drives, up to 480 V for 400 V class drives), when protected by Bussmann
Type FWH fuses as specified in
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
AC Drive Input Amps
HP
100
142
170
150
207
250
300
300
346
350
410
584
Three-Phase 600 V Class
2
3.6
3
5.1
5
8.3
7.5
12
10
16
15
23
20
31
25
38
30
33
40
44
50
54
60
66
75
80
100
108
125
129
150
158
200
228
Table D.9 Control Circuit Terminal Power Supply
Terminal Signal
P1, C1, P2, C2, DM+, DM-
S1-S8, SN, SC, SP, HC, H1, H2
+V, -V, A1, A2, AC, AM, FM
Table
D.1.
L1000A in Heavy Duty Mode (C6-01 = 0)
MCCB Rating
Time Delay Fuse
Amps
Rating Amps
<1>
225
225
250
250
350
350
500
500
600
600
700
700
1000
1000
<4>
15
6.25
15
8
15
12
20
20
30
25
40
40
60
50
75
60
60
50
75
75
100
90
125
110
150
125
175
175
250
225
300
250
400
350
Requires class 2 power supply
Use the internal LVLC power supply of the drive. Use class 2 for
external power supply.
D.3 UL and CSA Standards
Bussmann
Non-time Delay Fuse
Semiconductor Fuse
Rating Amps
Rating (Fuse
<2>
<3>
Ampere)
400
FWH-400A (400)
500
FWH-500A (500)
600
FWH-600A (600)
800
FWH-800A (800)
1000
FWH-800A (800)
<4>
1200
FWH-1000A (1000)
<4>
1600
FWH-1200A (1200)
<4>
10
FWP-50B (50)
15
FWP-60B (60)
20
FWP-60B (60)
35
FWP-70B (70)
45
FWP-100B (100)
60
FWP-100B (100)
90
FWP-125A (125)
100
FWP-125A (125)
90
FWP-175A (175)
125
FWP-175A (175)
150
FWP-250A (250)
175
FWP-250A (250)
225
FWP-250A (250)
300
FWP-350A (350)
350
FWP-350A (350)
400
FWP-600A (600)
600
FWP-600A (600)