YASKAWA L1000A Technical Manual page 263

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

S3-26: DC Injection Gain in Motoring Operation
In OLV Control, S3-26 sets a gain level for DC Injection at stop (S1-03) when the motoring load reaches 100%. At that
time, the current applied during DC Injection at stop is determined as S1-03 × S3-26.
No.
S3-26
S3-27: Torque Compensation Value with Load Condition 1
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 131
for details.
No.
S3-27
S3-28: Torque Compensation Value with Load Condition 2
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 131
for details.
No.
S3-28
S3-29: Analog Input from Load Sensor with Load Condition 1
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 131
for details.
No.
S3-29
S3-30: Analog Input from Load Sensor with Load Condition 2
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 131
for details.
No.
S3-30
S3-34: Anti-Rollback Torque Bias 1
Sets an intermediary value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This
setting rarely needs to be changed.
No.
S3-34
S3-35: Anti-Rollback Torque Bias 2
Sets a maximum value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This setting
rarely needs to be changed.
No.
S3-35
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Parameter Name
DC Injection Gain in Motoring Operation
Parameter Name
Torque Compensation Value with Load Condition 1
Parameter Name
Torque Compensation Value with Load Condition 2
Parameter Name
Analog Input from Load Sensor with Load Condition 1
Parameter Name
Analog Input from Load Sensor with Load Condition 2
Parameter Name
Anti-Rollback Torque Bias 1
Parameter Name
Anti-Rollback Torque Bias 2
5.11 S: Elevator Parameters
Setting Range
0 to 400%
Adjusting the Torque Compensation at
Setting Range
-100.0 to 100.0%
Adjusting the Torque Compensation at
Setting Range
-100.0 to 100.0%
Adjusting the Torque Compensation at
Setting Range
-100.0 to 100.0%
Adjusting the Torque Compensation at
Setting Range
-100.0 to 100.0%
Setting Range
0.0 to 100.0%
Setting Range
0.0 to 100.0%
Default
20%
Default
-50.0%
Default
50.0%
Default
0.0%
Default
100.0%
5
Default
0.0%
Default
0.0%
263