Connecting the Drive and Battery
Use the 1.1 m cable packaged with the drive to connect the battery. Remove the connector covering port CN19 before
connecting the cable to CN19.
Information on battery power ratings can be found in
Note: The connector port location and angle vary by drive model.
DANGER! Switch off the power supply before wiring and connecting the battery cable. Failure to comply will lead to death or serious
injury from electric shock.
Battery Connections for CIMR-LU20008 to 20075, CIMR-LU40005 to 40039, and CIMR-LU50003 to
50027
1.
Insert the tip of a screwdriver into the opening on the edge of the CN19 connector cover. Slide the cover off the
drive as indicated in
NOTICE: A straight-edge screwdriver should be inserted into the opening provided on the connector cover at the proper angle.
Attempting to insert the screwdriver blade at a different angle could damage the drive.
Figure 4.24
2.
Connect the cable provided to the CN19 port.
NOTICE: Be sure that the connector fastens at the correct angle to the drive port. The incorrect angle could damage the battery, cable,
or connector.
Figure 4.25
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Table
Figure
4.29.
Press inwards on the tab and
slide the connector cover in the
direction indicated by the arrow.
Figure 4.29 Removing the Connector Cover
Figure 4.30 Connecting the Cable
4.6 Setup Procedure for Elevator Applications
4.13.
Port CN19
Press in on the connector
clip to plug in the cable.