Chapter 15: Maintaining Your Library
Maintenance Actions
598
• Frame test - This test includes the same individual tests as the Install
Test, but enables you to specify a range of modules rather than
testing all modules.
• Configuration test - This test includes the picker assembly and
scanner fiducial tests.
Both tests enable you to select a range of modules and racks to test. For
example, if you have a four-module library, you can select to test only
modules 3 and 4. The Frame test performs the same operations as the
installation verification test, except there are frame and rack range
parameters available.
FRU Test
The FRU test enables you to verify the replacement of a FRU. When the
FRU test is selected, you can select any of the following sub-tests:
• Accessor Assembly
• Picker Assembly
• Drive Sled Assembly
• IE Assembly
• Scan Barcode
When one of the sub-tests is selected, you may be prompted to enter
additional information. For example, the Select FRU dialog box has tabs
along the top to select individual drives, I/E stations, and scratch tapes.
Custom Test
The Custom test enables you to run the Library Alignment sub-test on a
per-rack basis.

Sub-test Descriptions

Use the Verification Tests dialog box to select the test and sub-test, to
start the test, and view results.
Verification Tests dialog box. To display the dialog box, click Tools >
Verification Tests.