Quantum Scalar i6000 User's Guide
• Last 6 Months — Test sessions that were run in the last six
months.
• All — All test sessions that were run on the library. The storage
limit is 50,000 media scans. When the limit is reached, old scan
results are deleted as new scan results are added.
3 To work with a session, click the test session row to highlight it, and
then click your desired option:
Option
Description
Stop
Stops a currently running test session. Once stopped,
you cannot restart the test. Any test results collected
so far are listed. Tapes that did not complete testing
as a result of being stopped show a test result of
Untested.
Pause
Pauses a currently running test session. The tape that
is being tested stays in the scanning drive. Tapes in
the test session that have not been tested yet will
remain queued.
Resume
Resumes a paused test session. Queued tapes are
mounted and scanned.
Details
Displays the test report for the selected test session in
a new window. See
Details
Delete
Deletes the selected test session from the list. Once
deleted, you cannot retrieve the information again.
Refresh
Refreshes the test session list so that the latest
information about the tests is displayed.
Chapter 9: Extended Data Lifecycle Management
Viewing EDLM Test Sessions and Report Details
Viewing EDLM Session Report
on page 344.