Xerox DocuColor 2240 Service Manual page 1151

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
760-069
Skew Alarm threshold
DC3535
760-070
Y-LD light volume at last RegiCon
760-071
M-LD light volume at last RegiCon
760-072
C-LD light volume at last RegiCon
760-073
K-LD light volume at last RegiCon
760-074
Y-XSO after LD light volume change
760-075
M-XSO after LD light volume change
760-076
C-XSO after LD light volume change
760-077
K-XSO after LD light volume change
760-078
Y-XBI after LD light volume change
760-079
M-XBI after LD light volume change
760-080
C-XBI after LD light volume change
760-081
K-XBI after LD light volume change
760-082
Specified LD light quantity [Y]
DC3535
760-083
Specified LD light quantity [M]
DC3535
760-084
Specified LD light quantity [C]
DC3535
760-085
Specified LD light quantity [K]
DC3535
760-090
Frequency of RegiCon implemented at
DC3535
the same time as ProCon
760-091
YSO at Y-165mm/s
DC3535
760-092
YSO at M-165mm/s
DC3535
760-094
YSO at K-165mm/s
DC3535
760-095
Y-X direction speed correction amount
DC3535
760-096
M-X direction speed correction amount 17
DC3535
760-097
C-X direction speed correction amount 16
DC3535
760-098
K-X direction speed correction amount 16
DC3535
760-099
Process speed at last Regi-Con
DC3535
760-100
Y-Y margin speed switch variation
DC3535
General Procedures and Information
760-xxx Regicon NVM List
Table 1 Chain 760
Default
Range
Description
30
0~255
Threshold of Skew amount; if this value is exceeded, it is registered as a failure. (2µm/bit)
0
0~1023
Laser Diode light quantity when Regi Control is performed.
0
0~1023
Laser Diode light quantity when Regi Control is performed.
0
0~1023
Laser Diode light quantity when Regi Control is performed.
0
0~1023
Laser Diode light quantity when Regi Control is performed.
236
0~472
XSO value after correction based on the Laser Diode light quantity variation
236
0~472
XSO value after correction based on the Laser Diode light quantity variation
236
0~472
XSO value after correction based on the Laser Diode light quantity variation
236
0~472
XSO value after correction based on the Laser Diode light quantity variation
0
0~3
XBI value after correction based on the Laser Diode light quantity variation
0
0~3
XBI value after correction based on the Laser Diode light quantity variation
0
0~3
XBI value after correction based on the Laser Diode light quantity variation
0
0~3
XBI value after correction based on the Laser Diode light quantity variation
0
0~1023
Current Laser Diode light quantity (LD light quantity specified by ROS)
0
0~1023
Current Laser Diode light quantity (LD light quantity specified by ROS)
0
0~1023
Current Laser Diode light quantity (LD light quantity specified by ROS)
0
0~1023
Current Laser Diode light quantity (LD light quantity specified by ROS)
3
0~16
in what cycle RegiCon should be implemented at the same timing as ProCon during job
237
0~474
1 dot
237
0~474
1 dot
237
0~474
1 dot
17
0~32
1/4 dot
0~32
1/4 dot
0~32
1/4 dot
0~32
1/4 dot
0
0~1
0=RegiCon last implemented at 104 or 52mm/s; 1=RegiCon last implemented at 165mm/sec.
156
0~200
(Y margin variation amount when the speed is switched from 104 or 52mm/sec. to 165mm/s)-100, for Yellow
(1 µm/bit)
09/03
6-60
Initial issue
DC 3535/2240/1632, WC M24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 3535Docucolor 1632Workcentre m24