REPLACEMENT AND ADJUSTMENT OF PARTS

4.2 SOS Sensor Assembly

[Disassembly]
Warning:
Turn off the power switch and disconnect the power supply cord from the wall outlet.
Remove the EP toner cartridge and keep it in a safe place.
The ROS must not be running while it is being handled.
(1) Turn the printer over onto its top cover. (Turn it upside down.)
(2) Remove the following units:
• Bottom cover (Refer to section 1.4)
• ROS assembly (Refer to section 4.1)
• Screw [1]
• SOS sensor assembly [2]
[Assembly]
Reverse the disassembly procedure.
[2]
[1]