2.6 Pre-Regi. Sensor

[Disassembly]
Warning:
Turn off the power switch and disconnect the power supply cord from the wall outlet.
Remove the EP toner cartridge and keep it in a safe place.
(1) Remove the following units:
• Top cover (Refer to section 1.2)
• Feeder assembly (Refer to section 2.1)
Unhook the pre-regi. sensor clips [2] on the back of the feeder frame and remove the pre-regi.
sensor [1].
[Assembly]
Reverse the disassembly procedure.
REPLACEMENT AND ADJUSTMENT OF PARTS
Pre-regi. sensor [1]
[1]
– 35 –
Be sure that the power is disconnected!
[2]