4.5 Mirror
[Disassembly]
Warning:
Turn off the power switch and disconnect the power supply cord from the wall outlet.
Remove the EP toner cartridge and keep it in a safe place.
The ROS must not be running while it is being handled.
(1) Turn the printer over onto its top cover. (Turn it upside down.)
(2) Remove the bottom cover. (Refer to section 1.4)
(3) Disconnect CN122 [1] from the scanner [2].
(4) Disconnect CN121 [3] from the laser diode [4].
(5) Disconnect CN123 [5] from the SOS sensor [6].
(6) Remove the three screws [7] securing the ROS assembly.
[5]
[Assembly]
Reverse the disassembly procedure.
Caution:
Do not scratch or touch the front surface of the mirror with your hand; also, be sure to use the mirror clips
[9] to install it on the ROS assembly.
REPLACEMENT AND ADJUSTMENT OF PARTS
[7]
[6]
– 51 –
Be sure that the power is disconnected!
[1]
[2]
[4]
[3]