MAINTENANCE GUIDE
REG. SCAN
Adjusts the registration marks at
the top and bottom of the page.
8
FUSER TEMP. SET
Sets the temperature of the fuser con-
9
troller.
INPUT TRAY SIZE
A
Sets the paper size for the input tray.
I/F OPTION
Sets special interface specifications.
B
Caution 1: The non-volatile code can only be changed if it is possible to change the settings.
If the table shows that it is "Not Possible" to change the settings, then the settings cannot be changed
and are determined by the setting in the OEM.
If it is "Possible" to change the settings, be sure the settings are changed correctly.
Caution 2: The settings for non-volatile codes not mentioned in the table above cannot be changed.
Note:
Non-volatile code A has the same function as the input tray paper setting in user settings mode.
Entering the settings in user settings mode is easier than using the non-volatile mode to make these
settings.
0 ~ 8 (9 levels) [Preset Value 4]
0 indicates that the minimum amount of blank
space will be left on the left side of the page
and 8 indicates that the maximum amount of
blank space will be left on the left side of the
page.
• Changes in 4C increments.
(There are 5 levels within each temperature
code.)
0 ~ F (16 levels) [Preset Value 8]
0 indicates that the fuser controller will be set
at the lowest temperature and F indicates that
the fuser will be set at the highest temperature.
• Changes in 4C increments.
(There are 5 levels within each temperature
code.)
0 ~ F (16 levels) [Preset Value ____ ]
(Refer to section 3.1 Paper Size Controller.)
0 ~ F (16 levels) [Preset Value 0]
A value from 0 to F (hexadecimal number) is
entered as a binary number and is shown as
b3, b2, b1 or b0. The information for each bit
is shown below.
b0, b1, b2: NA (000: Fixed)
b3: Counter is displayed, TEST flag
(0: Invalid, 1: Valid)
– 74 –
Possible
Not possible
Possible
Not possible