Star Micronics WinType 4000 Technical Manual page 121

Table of Contents

Advertisement

2.1 U6
Step
1
(Initial Check)
Are any parts broken, malformed, incorrectly installed
or different from those listed in the specifications?
• Principle Parts to be Checked:
(1) MCU PWB
2
Does the problem recur if the power is turned OFF
and then ON again?
3
Does the problem recur if the power is turned OFF
and then ON one more time?
4
Does the problem recur if the power is turned OFF
and ON several times?
5
(Check the MCU PWB.)
Can non-volatile settings mode be entered if the
diagnostic tool is connected?
6
(Check the data in the non-volatile memory.)
Are the values of each of the non-volatile codes
correctly set?
7
(Check the MCU PWB.)
Are the values of each of the non-volatile codes
correctly setting, and does the problem recur if the
power is turned OFF and ON again?
*1: The problem is probably caused by external noise. In order to verify this, follow the troubleshooting procedure
described in section 3.16 Noise.
Caution:
If a U6 error occurs even though the MCU PWB has been replaced, follow the troubleshooting
procedure described in section 3.16 Noise.
Check
– 117 –
TROUBLESHOOTING
Remedy
YES
Replace the part or
install the part
correctly.
See step 5.
See step 5.
See step 5.
See step 6.
Replace the MCU
PWB.
Replace the MCU
PWB.
NO
See step 2.
See step 3.
See step 4.
Countermeasure is
completed. *1
Replace the MCU
PWB.
See step 7.
See step 4.