6-4. Adjusting Sensors
6-4-1. PE and BM Sensor Adjustment Mode
(1) Check that the printer is turned off.
(2) Unfasten the screw holding the DIP switch cover at the bottom of the printer, and remove the cover.
(3) Using a pointed object, set DIP switch DIPSW1-4 to OFF and DIP switches DIPSW1-5, DIPSW1-6, and DIPSW1-7 to ON.
DIP switch cover
(4) Open the front cover, and set a paper roll into the printer.
(5) Turn the printer on.
The lamps on the control panel will flash, and the printer will enter sensor adjustment mode.
(6) As shown in the figure below, turn VR1 with a precision flat-blade screwdriver so that both the POWER lamp (green) and
ERROR lamp (red) light.
OFF
ON
1
2
3
4
5
6
7
8
DIP-SW 1
VR1
VR2
- 30 -
9
10
1
2
3
4
DIP-SW 2