1.7.4 List of Diagnosis Codes

Diagnosis
Code
Counter
30
Input Test
02
07
08
80
90
91
Output
Test
92
93
94
95
00
00
00
Caution 1: Diagnosis code 00 ("EXIT DIAG.") can only be used to stop diagnosing in output test mode; it cannot
be used to initiate diagnosis mode.
Caution 2 : Only the diagnosis codes that are described above can be executed.
LCD Display
(Top Row)
PRINT COUNTER
SENSOR CHECK
FUSER TEMP. SET
FUSER TEMP.
SOLENOID TRAY0
MOTOR MAIN
HVPS (C.ROLL AC)
HVPS (C.ROLL DC)
HVPS (DEV.BIAS)
HVPS (T.ROLL –)
HVPS (T.ROLL +)
EXIT DIAG.
SIZE SENSOR
CHECK SUM
– 66 –
Operation
Displays the number of pages to be printed.
Shows whether or not the switches and sensors are
operating properly.
Displays a temperature code corresponding to the
temperature set in the fuser controller.
Displays a temperature code corresponding to the
present temperature of the fuser.
Operates the feed solenoid in the input tray (for 0.5
seconds only).
Operates the main motor in the drive assembly.
The HVPS applies an AC voltage to the charge roller
(CR).
The HVPS applies a DC voltage to the charge roller
(CR).
The HVPS applies a –DC/AC voltage to the magnetic
roller (DB).
The HVPS applies a –DC voltage to the bias transfer
roller (TR(–)).
The HVPS applies a +DC voltage to the bias transfer
roller (TR(+)).
Turns OFF the output test.
The main function does not operate.
Displays the SUM of the ROM.