System
I/O Device
801 Network Jack LAN Device Assignment
Prerequisite Program:
This screen assigns Strata CTX LAN
parameters, enabling PC applications
to connect to the BECU network jack.
1. From the Program Menu click
System > I/O Device. The
Equipment Assignment screen
displays.
2. Click the LAN Device tab. 801
Network Jack LAN Device
Assignments screen displays
(shown right).
3. Enter Program 801 data.
F
IELD
00 LAN Port Number
01 Protocol
02 PC Operation Type
03 Data Flow
4-30
803 on
page 4-28
and 804 on
D
ESCRIPTION
Enter the port number of the LAN device to be assigned. Refer to
CTI Port Assignments"
on
Possible values: 1~12 (default = no value)
Notes
•
Program the local port number for LCD Control of Voice Mail
•
Use the same Device Port No. (11) for Network BLF.
•
Use 10 for Network TPI
•
Use 12 for Network DSS
•
Network BLF and DSS are available only with CTX Release 1.3 or higher software
and with CTX WinAdmin Release 1.3 or higher software.
Select communication Protocol.
Possible values: TCP (default) or UDP
Note
Select UDP for Network DSS.
Select the Operation Type.
•
If Server is selected, enter 04 Server Port Number.
•
If Client is selected, enter the 05 Client IP Address.
Possible values: Server (default) or Client
Note
Select Client for TPI.
Select the data flow protocol for CTX and PC communications.
Note
If the logical device set up in
page 4-28
is set to CTI, this field must be set to Asynchronous data flow.
Possible values: Synchronization or Asynchronization (default = Asynchronization)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 11/03
page
4-32.
page
4-28.
"803 SMDR SMDI CTI Port Assignments"
6538
"803 SMDR SMDI
on