Station
Assignment
F
IELD
23 Travelling COS
Change
24 TGAC Override
25 Service Tones
26 CW and ROB Tone
27 Name Display
28 Door Ovr DND
30 Chg Sys Speed
31 Network COS
32 Auto OCA
33 Originate OCA
34 RSTU Supervision
35 Station SpDial Bins
36 Set SLT Dial Type
5-4
D
ESCRIPTION
Enable this station with the privilege to change the Travelling COS Override Code.
Possible values: Enable or Disable (default)
1
Enable Trunk Group Access Code (TGAC) override (for Attendant console) from
this station.
Possible values: Enable or Disable (default)
Disable Service Tone for Data Privacy.
Possible values: Enable (default) or Disable
Note
Service tone such as Call Waiting should be disabled for modems, faxes,
and similar devices.
Enable/Disable the station to receive Call Waiting (Campon) and Ring Over Busy
Tone.
Possible values: Enable (default) or Disable
Notes
CW tone is always two beeps.
ROB tone can be two beeps or continuous as set in PRG 204, 27.
Enable this station with the privilege to put the user name in the Directory
Assistance display of a large LCD.
Possible values: Enable (default) or Disable
Enable DND override by door phone.
Possible values: Override or Do not Override (default)
Enable this parameter to program System Speed Dial.
Possible values: Enable or Disable (default)
Select Network COS value.
Possible values: 1~32 (default = 1)
OCA occurs automatically when making a call to a busy station that allows OCA
calls to be received.
Possible values: Enable or Disable (default = Enable)
Enable this station with the privilege to make OCA calls to other stations.
Possible values: Enable (default) or Disable
This enables the auto disconnect Tandem timer in Program 104, FB06 for these
types of Connections.
Possible values: Received (default) or Not Received
Possible values: Devices connected to RSTU circuits that do not automatically
hang up, and connect to CO lines that do not provide disconnect
supervision, should be set with "Not Received."
The number of station speed dial bins allocated to this station:
Possible values: 0~100 (default = 0)
Choose DP (Old style - dial pulse dialling) or DTMF (Newer type - tone dialling).
Strata CTX Programming - Part 2: CTX WinAdmin Programming 11/03