Toshiba CTX100-S Programming Manual page 373

Strata ctx digital business telephone systems
Hide thumbs Also See for CTX100-S:
Table of Contents

Advertisement

Table 13-28
Programs 303~315 (continued)
Button
Sequence
306-18
Network COS
A7 '
C‚yq
C‚yq
, n,
,
307
OLG Delete
"&
C‚yq
,
307-00
OLG Number
C‚yq
C‚yq
n,
,
308
Trunk Timers
"'
C‚yq
,
308-00
Trunk Equipment No.
C‚yq
xxyyzz,
308-01
Auto Release
A7
C‚yq
, n,
,
308-02
Short Flash
A7!
C‚yq
, n,
,
308-03
Long Flash
A7"
C‚yq
, n,
308-04
Pause after Flash
A7#
C‚yq
, n,
308-04
Response Timer
A7$
C‚yq
, n,
309
Direct Inward Dialing
"(
C‚yq
,
309-00
ILG Number
C‚yq
n,
309-01
DID Number
A7
C‚yq
, n,
Strata CTX Programming - Part 3: Telephone Button Programming 11/03
Value(s)
n =
1~32
(default = 1)
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
xx =
Cabinet 1 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit 01~24
n =
1. Disable
2. Detect 95ms
3. Detect 450ms (default)
n =
0~15, where 1 = 100msec.
(default = 5, which is .5
seconds)
0 = no flash
n =
0, 5, 10, 15, 20, 25 and 30,
where 5 = .5 seconds.
(default = 20)
n =
0~5, 0 = immediately sent,
and 1sec.delay to
5sec.delay
(default = 1 second delay
before sending digits)
n =
0~3000
n =
1~32 (CTX100)
1~50 (CTX670 Basic)
1~128 (CTX670 Exp.)
n =
1~7 digits may include wild
card "?" where "?" = 0~9
Telephone Button Programming
Summary
Select Network COS number.
This command deletes Outgoing Line Groups.
Enter the OLG number to delete.
Assigns trunk timers for analog and T1 trunks.
Enter the trunk equipment number.
Note
Equipment numbers are required when assigning a new trunk
to the system. It can also be used to display the equipment
location of existing trunks.
Select the Automatic Release timing.
Note
Select Disable if the CO does not send the automatic release
signal to the loop start trunk.
Select Short Flash Time. When a telephone initiates the short flash
signal to the CO line it is connected to (using the short Flash feature
button or access code #450) the duration of a short flash is
determined by this command. Normally this signal is used to hook
flash a centrex line. The short flash range is 0 to 1.5 seconds in
increments of 0.1 seconds.
Select Long Flash Time. When a telephone initiates the long flash
signal to the CO line it is connected to (using the Long Flash feature
button or access code #451) the duration of a long flash is determined
by this command. Normally this signal is used to disconnect the line.
The long flash range is 0 to 3 seconds in increments of 0.5 seconds.
Pause time after flash: After a flash signal is sent to a CO line, this
timer determines when the line will start to send the dialed digits to
the other end.
The response timer is for analog DID/TIE lines that have the "start
method" set for "Timing" in Program 300-06. After a line is seized this
timer determines when the line will start to send the dialed digits to
the other end.
Possible Values 0=immediatly sent, and 50msec.delay to
500msec.delay. (default=500mseconds delay before sending digits).
This command assigns DID Number Analysis Table to ILG.
Select the ILG number.
Enter a DID number.
300 Series Programs
13-59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctx100Ctx670Strata ctx seriesStrata ctx100-sStrata ctx100Strata ctx670

Table of Contents