Note:
For Releases 2.0 and 2.1 of Communication Manager that use IA770, you cannot
Note:
remove messaging from the Media Gateway screen in the SAT interface before
the upgrade. Therefore, you must remove messaging from Slot V8 of the Media
Gateway screen after the upgrade, then administer the H.323 integration.
Completing pre-upgrade tasks — If the target S8300 is the primary
controller
!
CAUTION:
If you are upgrading an S8300 primary controller that has LSPs registered to it,
CAUTION:
the LSPs must be upgraded before the primary controller. (You can use the SAT
commands, list media-gateway or list survivable-processor, to see
if there are LSPs registered to the S8300.)
Perform the following procedures if you are upgrading an S8300 that is configured as a primary
controller:
To display IA770 alarms, if IA770 is enabled
●
To clear alarms
●
To check link status
●
To record all busyouts
●
To disable scheduled maintenance
●
To check for translation corruption
●
To save translations
●
To disable alarm origination
●
Note:
It is no longer necessary to disable Terminal Translation Initialization (TTI) before
Note:
an upgrade or to enable it after an upgrade.
To display IA770 alarms, if IA770 is enabled
1. On the Maintenance Web Interface, click Messaging Administration.
2. On the Messaging Administration menu, under Logs, click Alarm.
3. On the Alarm Log screen, type today's date. Leave the defaults in all other fields.
4. Click Display.
5. Resolve any alarms that are listed.