Manual upgrade of an S8300A and G700 to R4.0
In this case, do the following:
1. Add a name for the standard announcements backup set, for example, us-eng-backup.
2. Copy the standard announcements from the standard set, for example us-eng, to the
backup set.
3. Copy the announcements of the custom announcement set into the announcement set with
the standard name.

Stopping IA770

To stop IA770:
1. Type telnet 192.11.13.6 and press Enter.
2. Log in as craft or dadmin.
Note:
You must enter the commands in the next two steps using upper-case as
Note:
indicated.
3. Type stop -s Audix, and press Enter to shut down AUDIX. Note that the "A" in Audix
must be capitalized.
The shutdown takes a few minutes.
4. Type watch /VM/bin/ss, and press Enter to monitor the shutdown.
The watch command automatically refreshes every few seconds. When the shutdown is
complete, you see only the voicemail and audit processes. For example:
voicemail:(10)
audit http:(9)
Press Ctrl+C to break out of the watch command.
5. Type /vs/bin/util/vs_status, and press Enter to verify that AUDIX is shut down.
When AUDIX is shut down, you see the message
Voice System is Down.
!
Important:
After upgrading an S8300 media server, you must upgrade the G700 or G350
Important:
media gateway firmware and media module firmware before restarting IA770.
564 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server