Checking the number of allocated ports
!
CAUTION:
Release 4.0 of Communication Manager supports a maximum of 900 ports if the
CAUTION:
S8300 is a primary controller. If the existing system has more than 900 ports
allocated, then there may be a problem with the upgrade and you need to
escalate.
To check the system for the maximum number of ports
1. Type the SAT command, display system-parameters customer options and
press Enter.
2. Verify that the Maximum Ports: field is 900 or less.
Checking the availability of the FTP server for backing up data
During the installation and upgrade procedures, you must back up the system data to an FTP
server. You use a server on the customer's LAN for backups. A current version of the system
data is required to restore the system configuration upon completion of the upgrade.
Check with your project manager or the customer for the following information about the
●
FTP server.
- Login ID and password
- IP address
- Directory path on the FTP/SFTP/SCP server
!
Important:
Before going to the customer site, make sure that you can use a customer server
Important:
over the LAN for backups.
Obtaining S8300 software and G700 firmware
The files containing the software for the S8300 and the G700 and media module firmware are
on the Communication Manager Software Distribution CD-ROM that you take to the site. This
CD is called the software CD because it contains software for all of the Linux servers.
Additional files that may be needed are:
License file
●
Authentication file
●
Software service pack files (most recent version)
●
Before going to the customer site
Issue 10.2 May 2007
545