Ensuring the MGP default gateway IP address is set

Communication Manager release 4.0 requires that the built-in VoIP module of the G700 Media
Gateway has a default gateway IP address. To ensure that this IP address is set, perform the
following steps:
1. At the MG-???-1(configure)# prompt, type show ip route mgp.
The list of mgp routes appears.
MG-001-1(super)# show ip route mgp
DESTINATION
---------------
0.0.0.0
135.9.80.0
MG-001-1(super)#
2. Check that a Gateway IP address exists for Destination 0.0.0.0.
3. If a Gateway IP address does not exist, type, at the MG-???-1(configure)# prompt, set
ip route 0.0.0.0 0.0.0.0 <IP_address>, where <IP_address> is the default
gateway IP address.
After you reboot the media gateway, the IP address is active and available.

Setting rapid spanning tree on the network

Spanning Tree (STP) is a loop avoidance protocol. If you don't have loops in your network, you
don't need STP. The "safe" option is always to leave STP enabled. Failure to do so on a network
with a loop (or a network where someone inadvertently plugs the wrong cable into the wrong
ports) will lead to a complete cessation of all traffic. Rapid Spanning Tree is a fast-converging
protocol, faster than the earlier STP, that enables new ports much faster (sub-second) than the
older protocol. Rapid Spanning Tree works with all Avaya equipment, and can be
recommended.
Rapid Spanning Tree is set using the P330 stack processor command line interface.
To enable/disable spanning tree
1. Open a telnet session on the P330 stack processor, using the serial cable connected to the
Console port of the G700.
2. At the P330-x(super)# prompt, type set spantree help and press Enter to display the
set spantree commands selection.
3. To enable Spanning Tree, type set spantree enable and press Enter.
MASK
GATEWAY
---------------
---------------
0.0.0.0
135.9.80.254
255.255.255.0
135.9.80.88
Upgrade the firmware on the G700 Media Gateway
INTERFACE
----------
motfec0
motfec0
(F/C/U)
-----------
(3/0/165)
(101/0/0)