Saving Translations - Avaya G700 Installing And Upgrading

Hide thumbs Also See for G700:
Table of Contents

Advertisement

Manual upgrade of an existing S8300B or S8300C and G700 to R4.0
View Process Status screen
3. Make sure everything except ENV, arbiter, and dupmgr shows UP. Communication
Manager should show 65/65 UP or, if IA770 is installed, 67/67 UP.
The number of processes (67/67) may vary depending on the configuration. For a normal
state, the second number should not be greater than the first number. For example, the
numbers 66/67 UP would indicate that a process did not come up and should be
investigated before proceeding.
4. Using a telephone, make test calls to verify that call processing is working.
5. Run an IA770 sanity test:
a. At the Linux command line, type /vs/bin/display
b. All states should be Inserv with an associated phone number.
c. Retrieve the test message saved before the upgrade.

Saving translations

To save translations:
1. In the SSH session, open a SAT session.
2. Log in again as craft.
680 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server