Verifying start up of IA770 INTUITY AUDIX Messaging
To verify operation of IA770 INTUITY AUDIX Messaging, perform the following steps:
1. In the Maintenance Web Interface, under Server, click Process Status.
2. Select Summary and Display once and click View.
the View Process Status Results screen displays.
View Process Status screen
3. Make sure everything except ENV, arbiter, and dupmgr shows UP. Communication
Manager should show 65/65 UP or, if IA770 is installed, 67/67 UP.
The number of processes (67/67) may vary depending on the configuration. For a normal
state, the second number should not be greater than the first number. For example, the
numbers 66/67 UP would indicate that a process did not come up and should be
investigated before proceeding.
4. Using a telephone, make test calls to verify that call processing is working.
5. Run an IA770 sanity test:
a. At the Linux command line, type /vs/bin/display
b. All states should be Inserv with an associated phone number.
c. Retrieve the test message saved before the upgrade.
Complete the Installation of the S8300 (if the Primary Controller)
Issue 10.2 May 2007