Avaya G700 Installing And Upgrading page 703

Hide thumbs Also See for G700:
Table of Contents

Advertisement

To check for translation corruption
1. At the SAT prompt, type newterm and press Enter.
2. Enter your terminal type and press Enter.
If you see the message,
Warning: Translation corruption found
follow the normal escalation procedure for translation corruption before continuing the
upgrade.
To save translations
1. At the SAT prompt, type save translation and press Enter.
2. Under Command Completion Status you should see Success.
To disable alarm origination
If alarm origination is enabled during the upgrade, unnecessary alarms will be sent to the
Operations Support System (OSS) destination number(s). Even if you selected Suppress
Alarm Origination when you logged in, alarm origination will be automatically re-enabled when
the system reboots after the software upgrade. Use this procedure to prevent alarm origination
from being re-enabled after reboot.
!
CAUTION:
If you do not disable alarm origination, the system can generate alarms during
CAUTION:
the upgrade, resulting in unnecessary trouble tickets.
1. Logoff the SAT session.
2. At the command prompt, type almenable -d n -s n, where
-d n sets the dialout option to neither (number)
-s n disables SNMP alarm origination
Note:
Be sure to reset alarm origination after the upgrade.
Note:
3. Type almenable (without any options) to verify the alarm origination status.
You should see:
incoming: enable
Dial Out Alarm Origination: neither
SNMP Alarm Origination: n
On-site Preparation for the Upgrade
Issue 10.2 May 2007
703

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8300

Table of Contents