HP 1910 User Manual page 244

Hide thumbs Also See for 1910:
Table of Contents

Advertisement

Field
Type
Data
FCS
LLDPDUs encapsulated in SNAP
2.
Figure 200 LLDPDU encapsulated in SNAP
Table 72 Description of the fields in a SNAP-encapsulated LLDPDU
Field
Destination MAC address
Source MAC address
Type
Data
FCS
LLDPDUs
LLDP uses LLDPDUs to exchange information. An LLDPDU comprises multiple type, length, and value (TLV)
sequences, each carrying a type of device information, as shown in
Figure 201 LLDPDU encapsulation format
An LLDPDU can carry up 28 types of TLVs, of which the chassis ID TLV, port ID TLV, Time to Live (TTL) TLV,
and end of LLDPDU TLV are mandatory TLVs that must be carried and other TLVs are optional.
Description
Ethernet type for the upper layer protocol. It is 0x88CC for LLDP.
LLDP data.
Frame check sequence, a 32-bit CRC value used to determine the
validity of the received Ethernet frame.
Description
MAC address to which the LLDPDU is advertised. It is fixed to
0x0180-C200-000E, a multicast MAC address.
MAC address of the sending port. If the port does not have a MAC
address, the MAC address of the sending bridge is used.
SNAP-encoded LLDP Ethernet type for the upper layer protocol. It is
0xAAAA-0300-0000-88CC for LLDP.
LLDP data unit.
Frame check sequence, a 32-bit CRC value used to determine the
validity of the received Ethernet frame.
183
Figure
201.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents