Quantum Scalar i40 and Scalar i80 User's Guide
Note: If the library contains zero import/export (I/E) station slots, you
will not be able to import or export cleaning cartridges. See
Configuring I/E Station Slots
Note: The AutoClean or manual cleaning feature on the library
assumes that any tape cartridge imported into a cleaning slot is
a cleaning tape cartridge, regardless of the label on the
cartridge or type of cartridge. In order for a cleaning cartridge
to be recognized by the library as such, it must be imported
into the library cleaning slot(s). Be sure to label and import
cleaning cartridges appropriately. See
With Cartridges and Barcodes
page 164.
Note: This operation should not be performed concurrently by
multiple administrators logged in from different locations. You
can access the screen, but you cannot apply changes while
another administrator is performing the same operation.
Operator Panel
1 Select Setup > Dedicated Slots > Cleaning.
2 Press Modify.
3 Use the Up and Down buttons to select a value from zero to 4.
4 Press Apply.
5 Press Exit.
6 Save the library configuration (see
on page 106).
Web Client
1 Select Setup > Cleaning Slots.
2 Under the New Settings column, select the number of cleaning
slots to configure.
3 Under Setup Drive Cleaning Interval, the Current Settings column
lists the number of cleaning slots that are currently configured in
Chapter 4: Configuring the Library
Configuring Cleaning Slots
on page 62 for more information.
Chapter 11, Working
and
Valid Cleaning Cartridges
Saving the Library Configuration
on
61