Appendix B: Tape Alert Flag Descriptions
Table 11 Tape Drive Tape Alert
Flag Descriptions
No.
Flag
1
Read warning
2
Write warning
3
Hard error
4
Media
5
Read failure
6
Write failure
7
Media life
291
Recommended Application Client
Severity
Message
W
The tape drive is having problems
reading data. No data has been lost,
but there has been a reduction in the
performance of the tape.
W
The tape drive is having problems
writing data. No data has been lost, but
there has been a reduction in the
capacity of the tape.
W
The operation has stopped because an
error has occurred while reading or
writing data which the drive cannot
correct.
C
Your data is at risk:
1 Copy any data you require from this
tape.
2 Do not use this tape again.
3 Restart the operation with a different
tape.
C
The tape is damaged or the drive is
faulty. Call the tape drive supplier help
line.
C
The tape is from a faulty batch or the
tape drive is faulty:
1 Use a good tape to test the drive.
2 If the problem persists, call the tape
drive supplier help line.
W
The tape cartridge has reached the end
of its calculated useful life:
1 Copy any data you need to another
tape.
2 Discard the old tape.
Probable Cause
The drive is having
severe trouble
reading.
The drive is having
severe trouble
writing.
The drive had a hard
read or write error.
Media can no longer
be written/read, or
performance is
severely degraded.
The drive can no
longer read data from
the tape.
The drive can no
longer write data to
the tape.
The media has
exceeded its specified
life.