No.
Flag
21
Cleaning
requested
22
Expired
cleaning media
23
Invalid cleaning
tape
24
Retension
requested
25
Multi-port
interface error
on a primary
port
Quantum Scalar i40 and Scalar i80 User's Guide
Recommended Application Client
Severity
Message
W
The tape drive is due for routine
cleaning:
1 Wait for the current operation to
finish.
2 Then use a cleaning cartridge.
Check the tape drive user's manual for
device-specific cleaning instructions.
C
The last cleaning cartridge used in the
tape drive has worn out:
1 Discard the worn-out cleaning
cartridge.
2 Wait for the current operation to
finish.
3 Then use a new cleaning cartridge.
C
The last cleaning cartridge used in the
tape drive was an invalid type:
1 Do not use this cleaning cartridge in
this drive.
2 Wait for the current operation to
finish.
3 Then use a valid cleaning cartridge.
W
The tape drive has requested a
retension operation.
W
A redundant interface port on the tape
drive has failed.
Appendix B: Tape Alert Flag Descriptions
Probable Cause
The drive is ready for
a periodic cleaning.
The cleaning cartridge
has expired.
Invalid cleaning
cartridge type used.
The drive is having
severe trouble
reading or writing,
which will be resolved
by a retension cycle.
Failure of one
interface port in a
dual-port
configuration (for
example, Fibre
Channel).