5.
Mount the throttle body onto the engine.
6.
Temporarily reconnect the battery, positive (red> lead
first.
Z
Attach the Triumph diagnostic tool to the dedicated
plug, refer to the Triumph Diagnostic Tool User
Guide.
8.
Turn the ignition to the 'ON' position.
9.
On
the
diagnostic tool
Diagnostics' and select the 'Adjust Tune' button.
10. Select 'Idle Speed Control Stepper Renew' then
press the 'Ad just' button.
1 1.
On pressing the 'Adjust' key, the diagnostic tool wil l
send a command that drives the throttle t o the fully
closed position. The tool will a lso display the voltage
reading coming from the throttle position sensor
which should be between the target voltage range of
0.58V and 0.6 2V.
Adjust Tu ne Procedure
Adjust the throttle position sensor as described in the service manual
u ntil the voltage reading is within the range shown below
OK
Press
when the adjustment is complete
Press cancel to cancel the adjustment process
Throttle Voltage :
Target Voltage Range:
Adjusting parameter - Throttle Position Sensor Adjust
Adjust Tune Screen
12. Tighten the stepper a rm nut on the idle speed
stepper motor until a clearance of 0.5 mm can be
measured between the idle speed control cam and
the throttle rol ler.
1. Idle speed control lever
2. Throttle roller
navigate to
'Engine
0.59 V
0.58 V - 0 . 62 V
SeiVice Manual
Tiger 800 and Tiger 800XC
-
Fuel System/Engine Management
1 3 .
Check the voltage reading shown on the software. I f
the reading i s between the target voltage range,
then proceed to step 1Z If the reading is not within
this range, adjustment must be made as described in
steps 14 to 1 6.
14.
Slacken the screws on the throttle position sensor.
15.
Gently turn the throttle position sensor until the
voltage reading shown on the software is between
the target voltage range.
16.
Tighten the sensor retaining screws to
recheck the voltage reading shown on the software.
Repeat the adjustment if the reading is outside the
specified range.
1Z
Click the 'OK' button to prog ress to the next
adjustment.
Note:
The diagnostic software will calculate the
target voltage range for when the throttle is
in the fully open position.
18.
On pressing the 'OK' button, the d iagnostic tool will
send a command that drives the throttle to the fully
open position. The tool will also display the voltage
reading coming from the throttle . position sensor
which should be between the target voltage range
calculated by the software and shown on the screen.
19. With the stepper fully opened, check the voltage
shown on the software a nd, if necessary, adjust the
nut on the top of the stepper arm until the software
shows a voltage within the target voltage range
shown on the screen. The reading on the screen will
change from red to green, indicating that the
reading is correct.
1. Adjustment nut
and
2 Nm
10. 1 15