Chapter 8
Preparing for Manufacturing/Assembly

Viewing and Editing Export Properties

NI Ultiboard User Manual
The new setting uses the same properties as the Default setting, or the
setting that was last loaded. Refer to the Viewing and Editing Export
Properties section for information about changing the properties stored in
the new setting.
Complete the following steps to delete an export setting:
1.
Choose File»Export. The Export dialog box appears.
2.
Select the setting to be deleted from the Export settings drop-down
list.
3.
Click Delete. The setting is deleted from the Export settings
drop-down list.
Properties can be viewed and edited for each device or type of export. This
is done through the property dialog boxes that correspond to the devices or
types listed in the Export dialog box:
Gerber RS-274D
Gerber RS-274X
DXF
Board Statistics
Bill of Materials
Parts Centroids
NC Drill
Complete the following steps to display the properties dialog box for a type
of export:
1.
Select the item in the list displayed in the Export dialog box.
2.
Click Properties. The item's property dialog box appears.

Setting Gerber Properties

The Gerber properties (RS-274X or RS-274D) dialog box allows you to
select the layers to be exported, the number of digits in numerals, and the
kind of measurements:
Available layers list—Select the layers to export in this list and click
the -> button to move them to the Export Layers and Merged Layers
list (RS-274X only).
Units box—Select measurement system (Imperial or Metric).
Digits box—Define the number of integers and decimal places.
8-10