FF3
Offhook Signal Pattern
Offhook
Signal Pattern
Software Version: CPC-S and CPC'-M, Version 1.0 and higher
Address:
FF3 (ExtPort)# 16# (0 or l)#
Description
The offhook signaling tone can be sent repeatedly or only once.
Programming
FF3 (l-16
or l-24)#
16# (0 or l)#
Extension Port:
CPC-S: 1-16
CPC-M: l-24
O=Repeated tone burst
(approximately every 6 seconds).
l=Single tone burst.
Related
Programming
Offhook Signal: FF3 (ExtPort)# 7# (0 or l)#
Offhook Signal Volume: FF3 (ExtPort)# 15# (0 or l)#