FF2
DISA End Time
DISA End Time
Software Version: CPC-S and CPC-M, Version 1.0 and higher
Address:
FF2 (Trunk)# 20# (HHMM)#
Description
Use
this address to program a
DISA
trunk to stop DISA operation
at a
specified time each day. Trunks are enabled for DISA using the DISA Auto
Answer address (FF2 TrunH 1 l#). Use this DISA End Time address, and the
DISA Start Tnne address (previous page), to limit DISA operation on a trunk
to a certain time period each day.
NOTE:
The DBS 824 will disable DISA to the trunk one minute @er the
time set in this address. (In the example below, DISA will actually end when
the system clock reaches 8:16 am.)
Programming
To set the DISA end time . . .
Enter the time using the 24-hour format The following example sets the time
to 8: 15 a.m.
(DISA will actually end when the system clock reaches 8: 16 am.)
FF2 (l-6 qr l-8)## 2O# (0815)#
Trunk Number:
CPC-S: l-6
CPC-M: l-8
Time- Seui.ng
(24hour format)
To clear me
DISA end time . . .
FF2 (1-6or1-8)# 20# CONF ON/OFF
Related. Pro&nming
.-
TimeSetting: FFl l# 2# (HHMM)#
DISA Inbound Call ID Code: FFl 5# (0000-9999)#
DISA Outbound Call ID Code 1: FFl 6# l# (OOW9999)#
DISA Outbound Call ID Code 2: FFl 6# 2# (OOOO-9999)#
DISA Auto Answer: FF2 (Trunk)# ll# (0 or l)#
.
DISA Start Tie:
R
(Trunk)# 19# (HHMM)#
Notes
Caller
ID Automatic
DISA. This DISA End Tie setting does not affect
Automatic DISA operation with Caller ID (program address FF12# 8# l-lo#
PhoneNo.#) .