Before You Begin
Introduction to DBS 824 Programming
Initializing New Systems
Before programming
a newly installed DBS 824 system, set its programs to
the default values by performing
the following procedure.
Important: This procedure must be performed prior to programming
the
DBS 824 for the first time.
Failure to initialize the CPC (Central Processing
Card) may cause operational problems.
This initialization
procedure can also be used when you want to return all
changed programs to the default values.
1. Power-off the DBS 824 (set power switch to OFF).
2. Slide the CPC's SW1 switch to RAMCLEAR.
Figure I.
CPC memorv clear switch
POWar
Switch
Status LED
CAUTION:
Some early CPC cards
have RAM HOLD and
RAM CLEAR reversed.
Check the silk screen
I
CAUTION.
Settmg SW 1 to
.
RAM CLEAR Erases
l_/
Programmmg
8)
I _
A
0
I
Power Supphl
I
I
.
3. Power-on the DBS 824,
then wait until the bottom status LED on the
CPC card stopsjlashing (approximately 10 seconds).
4.
Slide SW1 to the RAMHOLD position.
Intro-4
DBS 824-l O-400
issued 3/l 195