SLT Onhook Flash Timer
FFl
SLT Onhook
Flash Timer
Software Version: CPC-S and CPC-M, Version 1.0 and higher
Address:
FFl 3# 12# (0-6)#
Description
Programming
This timer determines how long an SLT user must hold down the switchhook
before the
DBS 824
recognizes a hookflash.
A
setting is also provided to
prevent users from performing a hookflash on an
SLT.
FFl 3#I 12# (016)#
Timer Setting (Default=4;
see the following table)
Table I-17. SLTf2rzsh timer values
Notes
Number
Flash Treatment
No Detection
Valid Flash
Disconnect
0
Less than 200 ms
200 to 500 ms
Greater than 500
ms
1
Less than 200 ms
200 to 700 ms
Greater than 700 ms
2
Less than 200 ms
200 to 1000 ms Greater than 1000
ms
3
Less than 200 ms
200 to 1200 ms Greater than 1200 ms
Less than 200 ms 200 to 1500 ms Greater than 1500 ms
. Less than 200
ms
None
Greater than 200 ms
Less than 200 ms
200-500 ms
Greater than 500 ms
Reset Requirement. For changes to this program to take effect the system
must be turned off and then back on.