Trunk Circuit Type
Software Version: CPC-M Only (Version 1 .O and above)
Address:
FF2 (Trunk)# 21# (0 or l)#
Description
This program determines whether a trunk circuit in a CPC-M configuration is
loop-start, or if it will support Caller ID.
In a CPC-S configuration (which does not support Caller ID), all trunks are
loop-start.
Programming
FF2
(l-8)#
21# (0 or l)#
t
t
Trunk Number:
O=Loop-start.
CPC-M: 1-8
' l=Supports Caller ID.
Notes
CPC Card Requirement. This program address does not apply to the CPC-S
model, which does not support Caller ID. (Caller ID is a service offered by
local COs, that sends caller information to the DBS 824 system for incoming
calls.)
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off and back on.