Reminder Ring Timer - Vodavi STARPLUS Triad 1 System Programming Manual

Hide thumbs Also See for STARPLUS Triad 1:
Table of Contents

Advertisement

2-16
Description
The Automatic Call Back Timer invokes a call back anytime a user listens
to busy tone for a programmable period of time. By default, the
Automatic Call Back Timer is set for 03 seconds (enabled), and is variable
from 00-99 seconds. A value of 00 disables this timer. An Automatic Call
Back does not occur when this timer is disabled.

Reminder Ring Timer

Programming Steps
1. Press the REMINDER RING flex button (FLASH 01, Button #18). The
2. Enter a valid number that corresponds to 00-99 seconds in 1 second
3. Press HOLD to save the entry. A confirmation tone is heard and the
Description
When a CO line rings at a busy station, the call rings at the station using
muted ringing. The CO Line Ringing Option feature enables a user to
receive a reminder ring instead of muted ring. This timer provides a
reminder ring every time the timer expires, as long as the incoming CO
line remains connected.
If the user continues their present conversation and the CO party does
not hang up, the Reminder Ring timer expires and the user receives
another ring burst. When the key set user ends the existing call, ringing
for the CO call reverts to normal ringing.
By default, the Reminder Ring Timer is set to 00 second and is variable
from 00-99 seconds in 1 second increments.
following message displays:
R EMIN D ER R IN G
00
increments. A value of 00 disables the timer, therefore the user only
receives one ring burst at the beginning of the call.
display updates.