Error Codes
Code
Only one V.21 connection flag
2-11
was received
2-12
Modem clock irregularity
2-13
Modem initialization error
Counter overflow error of
2-22
JBIG chip
JBIG compression or
2-23
reconstruction error
2-24
JBIG ASIC error
JBIG data reconstruction error
2-25
(BIH error)
JBIG data reconstruction error
2-26
(Float marker error)
JBIG data reconstruction error
2-27
(End marker error)
JBIG data reconstruction error
2-28
(Timeout)
2-29
JBIG trailing edge maker error
The machine resets itself for a
2-50
fatal FCU system error
The machine resets itself
2-51
because of a fatal
communication error
D255/D256 FAX OPTION
Meaning
If error occurs frequently, change the settings
for resolution, paper size, and compression
type.
Turn OFF the main power, and then turn it back
ON.
Suggested Cause/Action
Replace the FCU.
Replace the FCU.
Turn OFF the main power, and then turn it
back ON.
Update the modem ROM.
Replace the FCU.
Turn OFF the main power, and then turn it
back ON.
JBIG data error
Check the sender's JBIG function.
Update the FCU ROM.
FCU defective
Check the destination device.
If this is frequent, update the ROM, or
replace the FCU.
If this is frequent, update the ROM, or
replace the FCU.