Ricoh M281 Series Service Manual page 497

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

SC No.
Type
SM
Error Name/Error Condition/Major Cause/Solution
ARDF position sensor defective
1. Rotate the ARDF inverter motor by hand to check
whether it is unusually difficult to rotate.
2. Check that the ARDF position sensor is not disengaged
and is correctly positioned. And check that the actuator
correctly shields the light.
3. Reconnect the following connector.
ARDF Position Sensor – IOB
4. If the connector is broken, shorted, or grounded,
replace the connector.
5. Replace the ARDF position sensor.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.