Service Call 501-582
SC No.
Type
SC549-00
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Fusing Lamp Disconnected Error
The fusing thermistor (center) temperature does not reach a
temperature of 100 degrees C within 30 seconds after the
machine starts warming up.
Connector pin defective
Triac defective
Fusing unit defective
Fusing thermistor connection PCB defective
IOB defective
PSU defective
Fusing lamp defective
The fusing thermistor (center) detects the temperature that
exceeds 235 degrees C.
The fusing thermistor (center) detects the temperature that
exceeds 195 degrees C in a heater-off state after the fusing
thermistor (center) detects the temperature of 155 degrees
C or less.
6-38