Ricoh M281 Series Service Manual page 449

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

SC No.
Type
SC142-00
D
SM
Error Name/Error Condition/Major Cause/Solution
White level detection error
The white level cannot be adjusted to the target level during auto
gain control.
Condensation in scanner unit
Scanner Carriage defective
BiCU defective
Harness defective
Connector disconnected
White Guide Plate dirty or attachment fault
Check if the SC occurs by turning the power OFF then ON. If the
SC occurs again, do the following steps. Check if the SC
reoccurs by cycling the power after each step.
1.
Reconnect the following connectors.
Scanner Carriage – BiCU connector
SBU – LEDB connector (SBU side connector which is
on the scanner carriage)
BiCU – IOB connector
2.
Check the white guide plate (exposure glass).
Check the white guide plate attached to the exposure glass.
If the white guide plate is in an unusual state, replace the
white guide plate.
3.
Scanner carriage defective
Replace the scanner carriage.
4.
BiCU defective
Replace the BiCU.
5.
Harness defective
Replace the following harnesses.
Scanner Carriage – BiCU harness
BiCU – IOB harness
6.
IOB defective
Replace the IOB.
6-11
Service Call 101-195
D255/D256/M281/M282

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D255 seriesD256M282M281-1D255-17

Table of Contents