SC672 (Controller start up error) is displayed
Symptom:
The following occur:
Communication error between operation panel and controller after machine is
SC672-00
powered on.
Communication error (receive) between operation panel and controller after
SC672-10
machine is powered on.
Communication error (send) between operation panel and controller after
SC672-11
machine is powered on.
Communication error between operation panel and controller after normal
SC672-12
start-up.
Communication error between operation panel and controller after normal
SC672-13
start-up; Operation panel not detected.
SC672 does not appear on the SMC report, as it is not logged.
The Smart Operation Panel communicates with the controller via a USB cable and IPU.
SC672 is triggered when the panel cannot communicate with the controller.
Cause:
Possible causes of SC672 include:
USB communication path failure (USB cable, IPU).
Controller boot up errors and/or operation panel boot up errors due to an abnormal break
in operations of the controller.
Possible causes of operation panel cannot light include:
USB communication path failure (USB cable, IPU).
Operation panel cannot communicate with controller due to controller boot-up error.
Solution:
Do the following.
1.
Turn the machine power OFF/ON.
2.
Do the action in the flowchart below to determine the cause and best course of action when
SC672 occurs.
If the SC recurs after you do the action in this flowchart, do the following:
If SC819 (cache error) appears in the SC history, replace the controller board.
If SC991 (SCS: scs time count level c') appears in the SC history, replace the
controller board and USB cable.
SM
6-119
Troubleshooting Guide
D255/D256/M281/M282