Service Call 900-998
6.10.2 SC900 (CONTROLLER)
SC No.
Type
SC900-00
A
SC No.
Type
SC990-00
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Electric counter error
The electric total counter value is out of specification.
Error is detected when increasing the total counter.
Unexpected NV-RAM is attached.
NV-RAM defective
NV-RAM data corrupted.
Data written to unexpected area because of external factor
etc.
The count requested by the SRM on receiving PRT is not
completed.
Replace the NV-RAM.
Error Name/Error Condition/Major Cause/Solution
Software operation error
Software attempted an unexpected operation.
Parameter error
Internal parameter error
Insufficient work memory
Operation error caused by abnormalities that are normally
undetectable.
Turn the main power OFF/ON.
Reinstall the software of the controller board and BiCU.
6-90