Service Call 900-998
SC No.
Type
SC No.
Type
SC998-00
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Cases when SC997-00 does not occur;
1.
SCS sends command to the copy application.
2.
There has been no response from the copy application for
30 sec. (Error count value: 1)
Step1-2 is repeatedly performed 2 times. (Error count value:
4)
3.
SCS sends command to the copy application.
There has been response from the copy application. (Error
count value: 1)
The application ended by an unusual process.
Software bug (mainly the application)
Check the optional RAM/DIMM/boards required by the
application program.
Check if the combination of downloaded programs are
correct.
Error Name/Error Condition/Major Cause/Solution
Application start error
No application was registered to system within a specified
time after the main power was turned ON.
(No application starts/All applications have been terminated
abnormally)
Application started but cannot be drawn now for some
reason.
Software bug (mainly the application)
The optional RAM/DIMM/boards, required by the application
program, are not installed correctly.
Check the optional RAM/DIMM/boards required by the
application program.
Check if the combination of downloaded programs are
correct.
Replace the controller board.
6-92
SM