Ricoh M281 Series Service Manual page 416

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

UP/SP Data Import/Export
5.7.3 UP DATA IMPORT/EXPORT (SP 5300/5310)
Data that can be imported and exported
Paper Input
Maintenance
System
Print Settings
Security Options
Remote Services
Host Interface
Web Image Monitor Setting
Web Service Settings
Data that cannot be imported or exported
Address book
Programs (printer function)
Settings that can be specified via telnet
RICOH @Remote-related data
Counters
Settings that can only be specified via Web Image Monitor or Web Service (for example,
Bonjour, SSDP setting)
Settings for the date and time
Settings that require the device certificate
Settings that need to be adjusted for each printer (for example, image adjustment settings)
Settings exclusively for executing functions and settings exclusively for viewing
Exporting Device Information
This can be exported / imported by an administrator with all privileges.
When exporting SP device information from the control panel, the data is saved on an SD card.
1.
Remove the controller cover. (page 4-67)
2.
Insert the SD card into the SD Card Slot 2 (lower) [A].
D255/D256/M281/M282