Service Call 303-396
SC No.
Type
SC No.
Type
SC396-02
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Connector disconnected or defective
Reconnect the following connector. Then perform a
conduction inspection. If there is no conduction, replace the
connector.
IOB – Drum Motor connector
Drive transmission of the drum motor defective
Check the gears. If any gears are damaged, replace them.
Drum motor defective
Replace the drum motor.
IOB defective
Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Drum Motor Error 2
After the drum motor is stabilized, the stable OFF signal is
detected for 2 seconds consecutively.
Connector disconnected or defective
Drive transmission of the drum motor defective
Drum motor defective
IOB defective
Connector disconnected or defective
Reconnect the following connector. Then perform a
conduction inspection. If there is no conduction, replace the
connector.
IOB – Drum Motor connector
Drive transmission of the drum motor defective
Check the gears. If any gears are damaged, replace them.
Drum motor defective
Replace the drum motor.
IOB defective
Replace the IOB.