Key to perform reboot
# Cancel key is not displayed.
Turn on spanner LED (same as when an SC is generated).
Operation during SC reboot
Timing of SC reboot
When @Remote is enabled, and when a NRS alarm*1 is not generated, the
corresponding SC is the object of an automatic reboot.
*1 NRS alarm: Issued when an ordinary SC (type D) is generated twice while the total counter
counts 10 times.
Time to automatic reboot
Reboot is performed 30 seconds after an engine reboot is possible, after the end of
post-processing during printing, etc.
At that time, a reboot is performed even if the machine is operating. The engine does not
start process control when a reboot is possible.
Automatic reboot
See the flowchart below.
SM
6-3
Self-Diagnostic Mode
D255/D256/M281/M282