Ricoh M281 Series Service Manual page 478

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

Service Call 501-582
SC No.
Type
SC No.
Type
SC551-00
D
D255/D256/M281/M282
Error Name/Error Condition/Major Cause/Solution
Fusing thermistor connection PCB defective
Replace the fusing thermistor connection PCB.
IOB defective
1. Update the engine software to the latest version.
2. Replace the IOB.
PSU defective
1. Reconnect the following connector.
PSU – IOB connector
2. Replace the PSU.
Fusing lamp defective
Replace the fusing unit.
Error Name/Error Condition/Major Cause/Solution
Fusing Thermistor (End) Disconnected Error
Input from fusing thermistor (end) is 1019 or more (A/D value)
continuously for 4 seconds.
Connector defective or disconnected
Connector pin defective
Triac defective
Fusing thermistor defective
Fusing thermistor connection PCB defective
IOB defective
Connector defective or disconnected
Reconnect the following connectors.
Fusing Thermistor – Fusing Thermistor Connection
PCB connector
Fusing Thermistor Connection PCB – IOB connector
Connector pin defective
If the I/F connector pins of the fuser unit and the main unit
are deformed owing to foreign materials, replace the
connectors or the units including the connectors.