Code
Meaning
The other terminal did not
0-30
reply to NSS(A) in AI short
protocol mode
The other terminal sent a
DCS, which contained
0-32
functions that the receiving
machine cannot handle.
The data reception (not ECM)
0-33
is not completed within 10
minutes.
Polarity changed during
0-52
communication
0-55
FCU does not detect the SG3.
The stored message data
0-56
exceeds the capacity of the
mailbox in the SG3.
The communication mode
specified in CM/JM was not
0-70
available
(V.8 calling and called
terminal)
The calling terminal fell back
to T.30 mode, because it
0-74
could not detect ANSam after
sending CI.
SM
Suggested Cause/Action
Check the connection.
Try adjusting the TX level and/or cable
equalizer settings.
The other terminal may not be compatible.
Reference:
Dedicated TX parameters - Section 4
Check the protocol dump list.
Ask the other party to contact the
manufacturer.
Check the connection.
The other terminal may have a defective
modem/FCU.
Check the connection.
Retry communication.
FCU firmware or board defective.
SG3 firmware or board defective.
SG3 firmware or board defective.
The other terminal did not have a
compatible communication mode (e.g., the
other terminal was a V.34 data modem and
not a fax modem.)
A polling TX file was not ready at the other
terminal when polling RX was initiated
from the calling terminal.
The calling terminal could not detect
ANSam due to noise, etc.
ANSam was too short to detect.
Check the connection and condition.
Try making a call to another V.8/V.34 fax.
27
Error Codes
D255/D256 FAX OPTION