Ricoh M281 Series Service Manual page 940

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

Bit Switches - 4
No
Function
0-3
Not used
4
DIS frame length
0: 10 bytes 1: 4 bytes
5
Not used
6
Forbid CED/ANsam output
0: Off
1: On (Forbid output)
7
Not used
No
Function
0
G3 protocol mode used
0: Standard and non-standard
1: Standard only
1-6
Not used
7
Short preamble
0: Disabled 1: Enabled
No
Function
0
DIS detection number
(Echo countermeasure)
0: 1
1: 2
1
Not Used
D255/D256 FAX OPTION
Do not change the settings.
1: The bytes in the DIS frame after the 4th byte
will not be transmitted (set to 1 if there are
communication problems with PC-based faxes
which cannot receive the extended DIS frames).
Do not change the setting.
Do not change this setting (Default: 0: Off),
unless communication problem is caused by a
CED or ANSam transmission.
Do not change this setting.
G3 Switch 02 (SP No. 1-105-003)
Change this bit to 1 only when the other end can
only communicate with machines that send
T.30-standard frames only.
1: Disables NSF/NSS signals (these are used in
non-standard mode communication)
Do not change the settings.
Refer to Appendix B in the Group 3 Facsimile
Manual for details about Short Preamble.
G3 Switch 03 (SP No. 1-105-004)
0: The machine will hang up if it receives the
same DIS frame twice.
1: Before sending DCS, the machine will wait for
the second DIS which is caused by echo on the
line.
Do not change the settings.
106
Comments
Comments
Comments
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D255 seriesD256M282M281-1D255-17

Table of Contents